Plastics piping systems for the transport of cold drinking water outside buildings can be certified with Kiwa Watermark to ensure quality. Kiwa quality statements under Kiwa evaluation guidelines BRL- K506, BRL- K522, BRL- K17101, BRL- K17102, BRL- K17104, BRL-K17105, BRL- K17201, BRL- K17202, BRL- K17301, BRL- K17401 and BRL- K17605.
Certification and testing for hoses, shower heads, hand showers and other sanitary tapware components with the Kiwa Watermark. Covering Kiwa evaluation guidelines BRL- K622, BRL- 658, BRL- K668, BRL- K14025, BRL- K14026, BRL- K14034.
Kiwa guarantees sustainable and safe sports facilities for many forms of sport. Kiwa conducts continuous research in our own laboratory. Before fields or facilities are tested on site, the products that are used to build sports surfaces are tested in the laboratory of Kiwa.
The quality of our drinking water is a matter that concerns us all. To prevent the pollution of drinking water it is essential for appliances (such as washing machines and dishwaters) to have internal backflow protection.
With the Kiwa Domes...
The products are intended to be used in in hot water installations with a working pressure of maximum.1 MPa (10 bar) and a water temperature of maximum 90 °C.
The shower hoses may be used in tap water installations with a maximum working pressure of 1000 kPa. The recommended limits for correct operation are a dynamic pressure between 100 kPa and 500 kPa and a water temperature of maximum 65°C.
Occasiona...
This approval requirement describes the requirements with regard to flexible hose assemblies for use in installations for natural gas with a pressure of no more than 200 mbar in accordance with the NPR 3378-11 Code of Practice
This approval requirement specify the requirements for fusion fittings made of polyethylene (PE) as well as of mechanical fittings for use in plastic piping systems for the supply of gaseous fuels of the 2nd and 3rd family according to EN 437 with a maximum operating pressure of 10 bar at a reference temperature of 20°C. The operating temperature is between -20 ˚C and 40 ˚C.
The products are intended to be used as gas pressure regulators, gas leak protectors and gas pressure regulators combined with gas leak protectors for domestic installations with a capacity up to 10 m3 and an inlet pressure (MOPu) up to 200 mbar a...
The products are intended to be used for the transport of drinking water and a working pressure of 1MPa (1,000 kPa), with a water temperature up to 65˚C and a maximum water temperature up to 90˚C for a period of maximum 1 hour.
Growers, growers associations and trading companies that ship their products directly from growers can use Kiwa once or periodically to monitor the quality of fresh produce. As an independent third party, Kiwa can also rule on conflicts between growers and buyers.
Fruit and vegetable companies can turn to Kiwa for the quality assessment of products during a fixed period under specific conditions. This shelf life check provides insight into how the quality of products develops over time. This can also be done in a benchmark in which comparable products of different origin, variety, suppliers and in different packaging are compared with each other.
An automatic sprinkler system must have a reliable pipe system for optimal operation. An internal Inspection of Sprinkler System Piping will give you an insight into the current condition of your sprinkler system.
You wish to call on Vinçotte Controlatom (member of Kiwa Group) for the radiation protection of your personnel, the public and your environment. This implies that you entrust us with the physical control tasks for your establishment authorized for ionizing radiation sources. The task of physical inspection is described in the Royal Decree of 20/07/2001, more precisely in Article 23. This legislation also covers all the operator's other duties relating to the radiation protection of personnel, the facility, the public and the environment. The department's physical control experts also comply with current international standards (ADR, ICRP, IAEA, etc.) and the recommendations and decisions of the Federal Nuclear Control Agency (AFCN).
Plastic piping products for drainage systems can be certified with the KOMO quality mark. KOMO quality statements under Kiwa assessment guidelines BRL- 1401, 1404, 1405, 1410, 1411 and 1412.
Products like copper tubes, steel pipes and other products intended for safe transport of drinking water can be certified with the Kiwa Watermark quality mark. Evaluation guidelines in this scope are BRL- K760, BRL- K761, BRL- K762, BRL- K767, BRL- K771, BRL- K772, BRL- K775, BRL- K795, BRL- K10018, BRL- K1028.
Certification of legionella prevention systems to prevent or reduce the growth of legionella bacteria in tap water installations. Kiwa Watermark assessment guidelines in this scope are BRL- 6010, BRL- K14010-1, BRL- K14010-2 and BRL- K14012.
When things go wrong, one needs a quick and reliable answer to a series of questions. For this experts are needed who have experience in a broad range of products and applications. Often a certain failure has occurred earlier in a total different application.